为准确测量镀锡板71钝化工艺铬酸溶液中的SO42-的浓度,研究了可见光分光光度仪及其检测方法的适用性,并对检测效果进行了产线验证。通过向铬酸溶液中滴加BaCl2,使SO42-与Ba2+生成BaSO4沉淀,再对比加药前后的铬酸溶液吸光度和透光率的变化,实现SO42-浓度的检测。为提高测试数据的准确性,使用铁氟龙亲水滤膜对铬酸溶液进行过滤,排除了铬酸溶液中杂质颗粒的干扰;通过向铬酸溶液中滴加盐酸,将Cr O42-转变为Cr_2O72-,排除了BaCrO4沉淀的干扰;对加药后的铬酸溶液进行超声波振荡,排除了BaSO4沉淀团聚对测试结果的干扰。实验发现:在分光光度计的测试波长> 570 nm时,光源可透过橙黄色的铬酸检测不透光的BaSO4沉淀颗粒,SO42-的浓度与样品的吸光度呈线性关系,与透光率呈负对数关系,据此建立硫酸根标准曲线。吸光度和透光率均可用于检测铬酸溶液中的硫酸根浓度,经与离子色谱法测试数据对比,测试准确度和精度均可满足产线的使用需求,大幅降低了检测成本。
Abstract:To accurately measure the concentration of SO42- in the chromic acid solution for the 71 passivation process of tinplate,the applicability of a visible spectrophotometer and its detection method was investigated,and the detection effect was verified in the production line.SO42- reacted with Ba2+to form BaSO4 precipitate by adding BaCl2 dropwise to the chromic acid solution,and then the concentration of SO42- was detected by comparing the changes in absorbance and light transmittance of the chromic acid solution before and after reagent addition.To improve the accuracy of test data,a Teflon hydrophilic filter membrane was used to filter the chromic acid solution to eliminate the interference of impurity particles in the solution.The hydrochloric acid was added dropwise to convert CrO42- into Cr_2O72-,thus avoiding the interference of BaCrO4 precipitate.Ultrasonic oscillation was applied to the chromic acid solution after reagent addition to eliminate the interference of BaSO4 precipitate agglomeration on the test results.The experimental results showed that when the test wavelength of the spectrophotometer was greater than 570 nm,the light source could penetrate the orange-yellow chromic acid and detect the opaque BaSO4 precipitate particles.The concentration of SO42- had a linear relationship with the absorbance of the sample and a negative logarithmic relationship with the light transmittance,based on which a sulfate radical standard curve was established.Both absorbance and light transmittance can be used to detect the sulfate radical concentration in chromic acid solution.Compared with the test data of ion chromatography,the test accuracy and precision can meet the application requirements of the production line,and the detection cost is greatly reduced.
[1]王琬,范纯,华犇,等.镀锡板71钝化表面铬含量测定方法研究[J].宝钢技术,2022(6):20~25.
[2]沈鹏杰,齐韦,万一群,等.镀锡板311钝化膜与71钝化膜的组织结构对比[J].电镀与涂饰,2024,43(8):34~41.
[3]许姣姣.镀锡板铬酸钝化工艺研究[J].电镀与精饰,2021,43(7):56~59.
[4]刘洋,朱启茂,何小琴,等.X射线荧光光谱法测定锡钢板71型钝化膜厚度[J].冶金分析,2024,44(8):67~71.
[5]王洺浩,陆永亮,翟运飞,等.钝化方式对镀锡板钝化膜组成与性能的影响[J].电镀与涂饰,2015,34(16):903~908.
[6]李建中,厉英.冷轧薄钢板表面镀锡/镀铬技术[M].北京:科学出版社,2016.
[7]胡如南,陈松祺.实用镀铬技术[M].北京:国防工业出版社,2005.
[8]冉广芬,马海州.硫酸根分析技术及应用现状[J].盐湖研究,2009,17(4):58~62.
[9]冯开文.实用电镀溶液分析方法手册[M].北京:国防工业出版社,2011.
[10]侯占忠.原子吸收法间接测定水中的硫酸根[J].张家口师专学报,2003,19(6):65~71.
[11]俞锦豪.ICP-AES法间接测定精盐水中硫酸根含量[J].氯碱工业,2000(4):40~41.
[12]王会存,施良,叶晓东.硫酸钡比浊法测定水中硫酸盐方法的改进[J].中国卫生检验,2010,20(5):1250~1250.
[13]叶峰.离子色谱法和分光光度法测定降水中硫酸根的比较[J].北方环境,2011,23(6):144~145.
[14]王婷,朱红霞,周敬峰,等.柱后衍生离子色谱法测定土壤和沉积物中的六价铬[J].中国环境监测,2023,39(5):236~242.
[15]吴小龙,陈琴放,符式锦,等.柱后衍生-离子色谱法测定土壤和沉积物中的六价铬[J].中国无机分析化学,2022,12(5):13~19.
[16]牛玉民,谢磊,马笑强.离子色谱法在环境检测中的应用及维护经验[J].清洗世界,2024,40(3):16~18.
[17]文芙蓉,陈平,温皓.ECO IC-863型离子色谱仪常见故障分析[J].仪器仪表与分析监测,2025(2):17~20.
[18]万家亮,梁沛任.分析化学[M].北京:高等教育出版社,2011.
[19]刘瑜年.浅谈分光光度法和分光光度计的原理及其应用[J].化工管理,2017(9):66~70.
[20]范以辉,惠焕强.浅谈分光光度法和分光光度计的原理及其应用[J].计量与测试技术,2006,33(12):11~12.
基本信息:
DOI:10.13630/j.cnki.13-1172.2026.0113
中图分类号:O657.3;TQ153.13
引用信息:
[1]段宗灿,齐韦,姚艳茹.分光光度法检测铬酸溶液中的SO_4~(2-)[J].河北冶金,2026,No.361(01):87-91.DOI:10.13630/j.cnki.13-1172.2026.0113.
2026-01-28
2026-01-28